Soldered Joints of Piezoelectric Products

Main Article Content

Olga E. Zheleznikova
Svetlana A. Mikaeva

Abstract

The paper considers issues related to the use of capillary luminescent flaw detection for monitoring glass-metal soldered joints of piezoelectric products. Standard methods of leakproofness testing of piezoelectric products are analysed; the framework for the applicability of each of them at the stages of the life cycle of piezoelectric products
is established. Based on the results of the studies, a capillary luminescent control method was chosen to check the tightness of glass-metal soldered joints in piezoelectric products. The stages of conducting a capillary luminescent method for monitoring glass-metal soldered joints of piezoelectric products are presented. A method for monitoring the tightness of piezoelectric products using the capillary luminescent method has been developed.

Article Details

How to Cite
Olga E. Zheleznikova, & Svetlana A. Mikaeva. (2020). Soldered Joints of Piezoelectric Products. Helix - The Scientific Explorer | Peer Reviewed Bimonthly International Journal, 10(05), 129-132. Retrieved from https://helixscientific.pub/index.php/home/article/view/236
Section
Articles